Aflati pretul pentru JUMO 608550/1080-643-00-0-874-8-106-2
Aflati pretul pentru JUMO The pointer contact thermometer with a stainless steel housing (material 1.4301, protection class IP 54) has a housing diameter of 80 mm. The measuring system used works on the principle of liquid expansion. The temperature is indicated by a pointer on a white scale with black lettering. The device has an accuracy class of 1.5 similar to DIN EN 13190. The temperature can be read through an acrylic glass pane (PMMA) in ° C or ° F. The built-in microswitch can be set to the desired switch-off temperature using a setpoint adjuster in the front window. The device is characterized by a high switching point accuracy of +/- 0.7 K based on the set switch-off point when the temperature rises. The maximum permissible switching capacity of the installed changeover contact is 5 amps / 230 volts AC. The electrical connection is made using screw terminals and is protected by a cover cap. The switching difference (hysteresis) is approx. 1.5% of the display range. After falling below the switch-off temperature, the microswitch automatically switches back to its original state. The contact adjustment is protected against improper adjustment by a cover. The thermometer is also equipped with a trailing pointer so that the maximum process temperature reached is recorded. The device has an immersion tube with a diameter of 8 mm made of CuNi and a screw connection made of brass. It is attached using a G 1 form A thread according to DIN 3852/2, the nominal position is arbitrary. The thermometer is used in particular in the transformer industry, but is also universally applicable for local temperature measurement of any kind. A decisive advantage is that no additional auxiliary energy is required for temperature measurement. The device is RoHS compliant and cadmium free.
![]() |
|
JUMO 00455918
The pointer contact thermometer with a stainless steel housing (material 1.4301, protection class IP 54) has a housing diameter of 80 mm. The measuring system used works on the principle of liquid expansion. The temperature is indicated by a pointer on a white scale with black lettering. The device has an accuracy class of 1.5 similar to DIN EN 13190. The temperature can be read through an acrylic glass pane (PMMA) in ° C or ° F. The built-in microswitch can be set to the desired switch-off temperature using a setpoint adjuster in the front window. The device is characterized by a high switching point accuracy of +/- 0.7 K based on the set switch-off point when the temperature rises. The maximum permissible switching capacity of the installed changeover contact is 5 amps / 230 volts AC. The electrical connection is made using screw terminals and is protected by a cover cap. The switching difference (hysteresis) is approx. 1.5% of the display range. After falling below the switch-off temperature, the microswitch automatically switches back to its original state. The contact adjustment is protected against improper adjustment by a cover. The thermometer is also equipped with a trailing pointer so that the maximum process temperature reached is recorded. The device has an immersion tube with a diameter of 8 mm made of CuNi and a screw connection made of brass. It is attached using a G 1 form A thread according to DIN 3852/2, the nominal position is arbitrary. The thermometer is used in particular in the transformer industry, but is also universally applicable for local temperature measurement of any kind. A decisive advantage is that no additional auxiliary energy is required for temperature measurement. The device is RoHS compliant and cadmium free.
Produsele recent vizualizate
Produse recomandate
![]() | Pepperl + Fuchs | V1S-W-3M-PVC |
![]() | Pepperl + Fuchs | NCB8-18GM50-Z5 |
![]() | Pepperl + Fuchs | NRN6-8GH40-E2-V1 |
![]() | Pepperl + Fuchs | V3-WM-20M-PVC |
![]() | Pepperl + Fuchs | GLP80-RT/40b/102/123/143 |
![]() | Pepperl + Fuchs | V3-WM-BK3M-PUR-U |
![]() | Pepperl + Fuchs | CAB-TC1200 |
![]() | Pepperl + Fuchs | NBB0,6-4GM22-E2-0,3M-V3 |
![]() | Pepperl + Fuchs | NBN8-F1-A0 |
![]() | Pepperl + Fuchs | VBG-CCL-G4F ASI-Ga |
![]() | Pepperl + Fuchs | MLV11-54-G/47/112 |
![]() | Pepperl + Fuchs | 3RG4022-3KB60-PF |
![]() | Pepperl + Fuchs | 3RG4024-0AG31-PF |
![]() | Pepperl + Fuchs | FB6208C |
![]() | Pepperl + Fuchs | UB800-18GM40A-E4-V1 |
![]() | Pepperl + Fuchs | NBB4-12GM50-E3-M |
![]() | Pepperl + Fuchs | CBN15-30GK60-A0 |
![]() | Pepperl + Fuchs | MW 9109 NOP 063,66 M10 012 |
![]() | Pepperl + Fuchs | ML300-55-2m-RT/59/103/115 |
![]() | Pepperl + Fuchs | V1-WV4A-3M-PUR |
![]() | Pepperl + Fuchs | LVL-M1-R31AA-P1ACNA-NA |
![]() | Pepperl + Fuchs | VAZ-SIMON-R2 |
![]() | Pepperl + Fuchs | VMCI-2+P-5M-PUR |
![]() | Pepperl + Fuchs | LT2-8-HS-2000/47/115 |
![]() | Pepperl + Fuchs | NBB5-18GM80-WS-V93 |
![]() | Pepperl + Fuchs | NCB50-FP-Z2-P1 |
![]() | Pepperl + Fuchs | PCV80-F200-R4-V15-LS221 |
![]() | Pepperl + Fuchs | Gender-Changer SUBD 25p-M/M |
![]() | Pepperl + Fuchs | UB800-F12-I-V15 |
![]() | Pepperl + Fuchs | MFT-D.1000 |