Aflati pretul pentru JUMO 701160/8-0153-001-25
Aflati pretul pentru JUMO The freely programmable temperature limiter / monitor according to DIN EN 14597 can be mounted on a top hat rail. The voltage supply is AC / DC 20 to 30 V, 48 to 63 Hz 5 VA. The universal measuring input is freely configurable for resistance thermometers, thermocouples as well as current and voltage signals. TB / TW monitor thermal processes in plants for a set limit. If this is exceeded, the built-in relay switches the system into an operationally safe state and the LED K1 switches from green to red. If the system comes back into the good area, the reset button on the TB must be unlocked manually with an appropriate tool. External unlocking is also possible. The TW, however, automatically resets itself without external influence. A binary output DC 24 V / 20 mA can output a pre-alarm signal at an adjustable temperature before reaching the limit value, which is additionally displayed via LED KV. The TB / TW with a width of 22.5 mm is mounted on top-hat rails and screw terminals with a cable cross-section of max. 2.5 mm² wired. He also has cULus approval.
![]() |
|
JUMO 00506486
The freely programmable temperature limiter / monitor according to DIN EN 14597 can be mounted on a top hat rail. The voltage supply is AC / DC 20 to 30 V, 48 to 63 Hz 5 VA. The universal measuring input is freely configurable for resistance thermometers, thermocouples as well as current and voltage signals. TB / TW monitor thermal processes in plants for a set limit. If this is exceeded, the built-in relay switches the system into an operationally safe state and the LED K1 switches from green to red. If the system comes back into the good area, the reset button on the TB must be unlocked manually with an appropriate tool. External unlocking is also possible. The TW, however, automatically resets itself without external influence. A binary output DC 24 V / 20 mA can output a pre-alarm signal at an adjustable temperature before reaching the limit value, which is additionally displayed via LED KV. The TB / TW with a width of 22.5 mm is mounted on top-hat rails and screw terminals with a cable cross-section of max. 2.5 mm² wired. He also has cULus approval.
Produsele recent vizualizate
Produse recomandate
![]() | Pepperl + Fuchs | RL28-8-H-700-RT/49/115 |
![]() | Pepperl + Fuchs | 3RG4023-0AB05-PF |
![]() | Pepperl + Fuchs | UB800-F12-I-V15 |
![]() | Pepperl + Fuchs | V23-GK |
![]() | Pepperl + Fuchs | NCN50-FP-Z4-V1 |
![]() | Pepperl + Fuchs | LT2-8-HS-6000/49/115 |
![]() | Pepperl + Fuchs | VAS-1A-K12-U-S1 SIMON |
![]() | Pepperl + Fuchs | MLV41-8-H-350-IR/59/95/136 |
![]() | Pepperl + Fuchs | UB500-F42S-E4-V15 |
![]() | Pepperl + Fuchs | RL31-8-2500-IR/115/136 |
![]() | Pepperl + Fuchs | 9416 Kabeld |
![]() | Pepperl + Fuchs | PB-SLPCC-01 |
![]() | Pepperl + Fuchs | V1S-TEE-V1/V1S |
![]() | Pepperl + Fuchs | V31-WM-MQ |
![]() | Pepperl + Fuchs | V1-WV2A |
![]() | Pepperl + Fuchs | E030124S |
![]() | Pepperl + Fuchs | NBB2-F29-E3 |
![]() | Pepperl + Fuchs | NCB1,5-12GM85-E2-D-V1 |
![]() | Pepperl + Fuchs | 3RG4012-3KB60-PF |
![]() | Pepperl + Fuchs | V3-GM-BK1,5M-PUR-U-V3-GM |
![]() | Pepperl + Fuchs | UB500-F42S-E6-V15 |
![]() | Pepperl + Fuchs | 10-236DX_A-2000 InkDIG |
![]() | Pepperl + Fuchs | ML300-P-6m-RT/25/98/103 |
![]() | Pepperl + Fuchs | GL50-RT/30/40a/98a |
![]() | Pepperl + Fuchs | V31-GM-3M-PVC-V31-GM |
![]() | Pepperl + Fuchs | CBX500-KIT-B19-IP65 |
![]() | Pepperl + Fuchs | P-LB-1.C.123 |
![]() | Pepperl + Fuchs | V1-G-OR1M-POC-V1-G |
![]() | Pepperl + Fuchs | MW 9109 NOP 063,66 M10 012 |
![]() | Pepperl + Fuchs | IPH-F15-V1 |