Aflati pretul pentru JUMO 601540/056-048-13-01-150-15/729,
Aflati pretul pentru JUMO The robust housing made of die-cast aluminum and the 150 mm long, stable steel immersion tube guarantee use even under rough conditions. Thanks to the rod expansion principle used, the flue gas temperature monitor can be used up to a maximum sensor temperature of 700 ° C. The maximum permissible ambient temperature on the housing (protection class IP54) is between -50 ° C and +80 ° C. A decisive advantage is that no additional auxiliary energy is required for temperature measurement. The electrical connection is made directly with screw terminals on the built-in microswitch, which can switch a maximum permissible switching capacity of AC 230 volts / 10 amps. A special feature of the built-in microswitch is the separation of two independent circuits. When the limit is set, the system switches from one circuit to the other. The thermostat has a switching difference (hysereesis) of 10 to 30 K and automatically switches back to its original state after the switch-off temperature has fallen below this value. The device is characterized by a fast reaction speed of ≤ 45 seconds in flue gas and is approved according to DIN EN 14597. The screw connection with a G 1/2 inch thread allows the device to be installed directly in the flue gas duct. The exhaust gas temperature monitor is used for all types of flue gas monitoring, in heating technology and solid fuel boilers for bivalent operation with oil boilers. The flue gas temperature monitor is also used when locking ventilation systems that cause negative pressure in combination with tiled stoves and fireplaces.
![]() |
|
JUMO 60000904
The robust housing made of die-cast aluminum and the 150 mm long, stable steel immersion tube guarantee use even under rough conditions. Thanks to the rod expansion principle used, the flue gas temperature monitor can be used up to a maximum sensor temperature of 700 ° C. The maximum permissible ambient temperature on the housing (protection class IP54) is between -50 ° C and +80 ° C. A decisive advantage is that no additional auxiliary energy is required for temperature measurement. The electrical connection is made directly with screw terminals on the built-in microswitch, which can switch a maximum permissible switching capacity of AC 230 volts / 10 amps. A special feature of the built-in microswitch is the separation of two independent circuits. When the limit is set, the system switches from one circuit to the other. The thermostat has a switching difference (hysereesis) of 10 to 30 K and automatically switches back to its original state after the switch-off temperature has fallen below this value. The device is characterized by a fast reaction speed of ≤ 45 seconds in flue gas and is approved according to DIN EN 14597. The screw connection with a G 1/2 inch thread allows the device to be installed directly in the flue gas duct. The exhaust gas temperature monitor is used for all types of flue gas monitoring, in heating technology and solid fuel boilers for bivalent operation with oil boilers. The flue gas temperature monitor is also used when locking ventilation systems that cause negative pressure in combination with tiled stoves and fireplaces.
Produsele recent vizualizate
Produse recomandate
![]() | Pepperl + Fuchs | 3RG4022-3KB60-PF |
![]() | Pepperl + Fuchs | LMR 00-2,0-2,0-K156 |
![]() | Pepperl + Fuchs | 3RG4022-0AG01-1AL0-PF |
![]() | Pepperl + Fuchs | UDC-18GM-400-3E1 |
![]() | Pepperl + Fuchs | ML300-8-1200-IR/25/115/120 |
![]() | Pepperl + Fuchs | NBB2-12GM60-A2-3G-3D xx3Gxx3D |
![]() | Pepperl + Fuchs | CAB-TC1200 |
![]() | Pepperl + Fuchs | V1S-W-3M-PVC |
![]() | Pepperl + Fuchs | V3-GM-YE2M-PVC-U |
![]() | Pepperl + Fuchs | NJ6-22-N-5M x23GxxxD |
![]() | Pepperl + Fuchs | NEB6-12GM50-E3-V1 |
![]() | Pepperl + Fuchs | NCN4-12GK35-N0 x2xG1xxD |
![]() | Pepperl + Fuchs | GLP80-RT/40b/102/123/143 |
![]() | Pepperl + Fuchs | NJ10-30GK50-A2 |
![]() | Pepperl + Fuchs | UB800-18GM40A-E4-V1 |
![]() | Pepperl + Fuchs | EPV-6000-SS-02 |
![]() | Pepperl + Fuchs | 3RG4012-3KB60-PF |
![]() | Pepperl + Fuchs | AD.M63.NPT2.BN.C.18.K01 |
![]() | Pepperl + Fuchs | IQT-F116-R4M-V1 |
![]() | Pepperl + Fuchs | Z 796 |
![]() | Pepperl + Fuchs | VAZ-T1-FK-0,25M-PUR |
![]() | Pepperl + Fuchs | NJ2-11-N-G-Y129365 12xG1xxD |
![]() | Pepperl + Fuchs | V31-WM-A2-1,5M-PUR-V1-G |
![]() | Pepperl + Fuchs | V3-8A-E2-5M-PUR |
![]() | Pepperl + Fuchs | MLV11-54-G/47/112 |
![]() | Pepperl + Fuchs | ANT2-8 2084/85 |
![]() | Pepperl + Fuchs | NBB5-18GM80-WS-V93 |
![]() | Pepperl + Fuchs | NBN40-U1-E2-C |
![]() | Pepperl + Fuchs | LVL-M1-R31AA-P1ACNA-NA |
![]() | Pepperl + Fuchs | V1-G-1,5M-PUR-V1-G |